CVE-2020-0986
Known exploited
High 7.8An elevation of privilege vulnerability exists when the Windows kernel fails to properly handle objects in memory, aka 'Windows Kernel Elevation of Privilege Vulnerability'.
Assigned by microsoft
Jun 9, 2020
CVE-2020-12023
Healthcare
Low 2.0Philips IntelliBridge Enterprise IBE Insertion of Sensitive Information into Log File
Assigned by icscert
Jun 11, 2020
CVE-2020-14062High 8.1FasterXML jackson-databind 2.x before 2.9.10.5 mishandles the interaction between serialization gadgets and typing, related to com.sun.org.apache.xalan.internal.lib.sql.JNDIConnectionPool (aka xalan2…
Assigned by mitre
Jun 14, 2020
CVE-2020-14060High 8.1FasterXML jackson-databind 2.x before 2.9.10.5 mishandles the interaction between serialization gadgets and typing, related to oadd.org.apache.xalan.lib.sql.JNDIConnectionPool (aka apache/drill).
Assigned by mitre
Jun 14, 2020
CVE-2020-14155Medium 5.3libpcre in PCRE before 8.44 allows an integer overflow via a large number after a (?C substring.
Assigned by mitre
Jun 15, 2020
CVE-2019-20838High 7.5libpcre in PCRE before 8.43 allows a subject buffer over-read in JIT when UTF is disabled, and \X or \R has more than one fixed quantifier, a related issue to CVE-2019-20454.
Assigned by mitre
Jun 15, 2020
CVE-2020-14195High 8.1FasterXML jackson-databind 2.x before 2.9.10.5 mishandles the interaction between serialization gadgets and typing, related to org.jsecurity.realm.jndi.JndiRealmFactory (aka org.jsecurity).
Assigned by mitre
Jun 16, 2020
CVE-2020-11899
Known exploited
Medium 5.4The Treck TCP/IP stack before 6.0.1.66 has an IPv6 Out-of-bounds Read.
Assigned by mitre
Jun 17, 2020
CVE-2020-14422Medium 5.9Lib/ipaddress.py in Python through 3.8.3 improperly computes hash values in the IPv4Interface and IPv6Interface classes, which might allow a remote attacker to cause a denial of service if an applica…
Assigned by mitre
Jun 18, 2020
CVE-2020-14416Medium 4.2In the Linux kernel before 5.4.16, a race condition in tty->disc_data handling in the slip and slcan line discipline could lead to a use-after-free, aka CID-0ace17d56824.
Assigned by mitre
Jun 18, 2020
CVE-2020-14477
Healthcare
Low 3.6Philips Ultrasound Systems Authentication Bypass Using an Alternate Path or Channel
Assigned by icscert
Jun 26, 2020
CVE-2020-11996High 7.5A specially crafted sequence of HTTP/2 requests sent to Apache Tomcat 10.0.0-M1 to 10.0.0-M5, 9.0.0.M1 to 9.0.35 and 8.5.0 to 8.5.55 could trigger high CPU usage for several seconds.
Assigned by apache
Jun 26, 2020
CVE-2020-15358Medium 5.5In SQLite before 3.32.3, select.c mishandles query-flattener optimization, leading to a multiSelectOrderBy heap overflow because of misuse of transitive properties for constant propagation.
Assigned by mitre
Jun 27, 2020
CVE-2020-8022High 7.7User-writeable configuration file /usr/lib/tmpfiles.d/tomcat.conf allows for escalation of priviliges
Assigned by suse
Jun 29, 2020
CVE-2020-12047
Healthcare
Critical 9.8The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard…
Assigned by icscert
Jun 29, 2020
CVE-2020-12043
Healthcare
Critical 9.8The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted.
Assigned by icscert
Jun 29, 2020
CVE-2020-12045
Healthcare
Critical 9.8The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded creden…
Assigned by icscert
Jun 29, 2020
CVE-2020-12041
Healthcare
Critical 9.4The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to netw…
Assigned by icscert
Jun 29, 2020
CVE-2020-12039
Healthcare
Low 2.4Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered…
Assigned by icscert
Jun 29, 2020
CVE-2020-12040
Healthcare
Critical 9.8Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication c…
Assigned by icscert
Jun 29, 2020
CVE-2020-12048
Healthcare
High 7.5Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on…
Assigned by icscert
Jun 29, 2020
CVE-2020-12037
Healthcare
High 7.5Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (P…
Assigned by icscert
Jun 29, 2020
CVE-2020-12035
Healthcare
Medium 4.9Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibr…
Assigned by icscert
Jun 29, 2020
CVE-2020-12036
Healthcare
High 7.5Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (P…
Assigned by icscert
Jun 29, 2020
CVE-2020-12024
Healthcare
Medium 6.1Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical acce…
Assigned by icscert
Jun 29, 2020
CVE-2020-12020
Healthcare
Medium 6.1Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13 and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 does not restrict non administrative users from gaining access to the operating system and editi…
Assigned by icscert
Jun 29, 2020
CVE-2020-12032
Healthcare
Critical 9.1Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems store device data with sensitive information in an unencrypted database.
Assigned by icscert
Jun 29, 2020
CVE-2020-12008
Healthcare
High 7.5Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system.
Assigned by icscert
Jun 29, 2020
CVE-2020-12016
Healthcare
Critical 9.8Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 a…
Assigned by icscert
Jun 29, 2020
CVE-2020-12012
Healthcare
Medium 6.1Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, an…
Assigned by icscert
Jun 29, 2020
CVE-2019-18254
Healthcare
Medium 4.6BIOTRONIK CardioMessenger II, The affected products do not encrypt sensitive information while at rest.
Assigned by icscert
Jun 29, 2020
CVE-2019-18256
Healthcare
Medium 4.6BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format.
Assigned by icscert
Jun 29, 2020
CVE-2019-18246
Healthcare
Medium 4.3BIOTRONIK CardioMessenger II, The affected products do not properly enforce mutual authentication with the BIOTRONIK Remote Communication infrastructure.
Assigned by icscert
Jun 29, 2020
CVE-2019-18248
Healthcare
Medium 4.3BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel.
Assigned by icscert
Jun 29, 2020
CVE-2019-18252
Healthcare
Medium 4.3BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes.
Assigned by icscert
Jun 29, 2020
CVE-2020-2021
Known exploited
Critical 10.0PAN-OS: Authentication Bypass in SAML Authentication
Assigned by palo_alto
Jun 29, 2020
CVE-2020-15069
Known exploited
Critical 9.8Sophos XG Firewall 17.x through v17.5 MR12 allows a Buffer Overflow and remote code execution via the HTTP/S Bookmarks feature for clientless access.
Assigned by mitre
Jun 29, 2020
CVE-2020-14145Medium 5.9The client side in OpenSSH 5.7 through 8.4 has an Observable Discrepancy leading to an information leak in the algorithm negotiation.
Assigned by mitre
Jun 29, 2020
CVE-2020-15415
Known exploited
Critical 9.8On DrayTek Vigor3900, Vigor2960, and Vigor300B devices before 1.5.1, cgi-bin/mainfunction.cgi/cvmcfgupload allows remote command execution via shell metacharacters in a filename when the text/x-pytho…
Assigned by mitre
Jun 30, 2020
CVE-2020-5902
Known exploited
Critical 9.8In BIG-IP versions 15.0.0-15.1.0.3, 14.1.0-14.1.2.5, 13.1.0-13.1.3.3, 12.1.0-12.1.5.1, and 11.6.1-11.6.5.1, the Traffic Management User Interface (TMUI), also referred to as the Configuration utility…
Assigned by f5
Jul 1, 2020
CVE-2020-15523High 7.8In Python 3.6 through 3.6.10, 3.7 through 3.7.8, 3.8 through 3.8.4rc1, and 3.9 through 3.9.0b4 on Windows, a Trojan horse python3.dll might be used in cases where CPython is embedded in a native appl…
Assigned by mitre
Jul 4, 2020
CVE-2020-15505
Known exploited
Critical 9.8A remote code execution vulnerability in MobileIron Core & Connector versions 10.3.0.3 and earlier, 10.4.0.0, 10.4.0.1, 10.4.0.2, 10.4.0.3, 10.5.1.0, 10.5.2.0 and 10.6.0.0; and Sentry versions 9.7.2…
Assigned by mitre
Jul 7, 2020
CVE-2020-9377
Known exploited
High 8.8D-Link DIR-610 devices allow Remote Command Execution via the cmd parameter to command.php.
Assigned by mitre
Jul 9, 2020
CVE-2020-8193
Known exploited
Medium 6.5Improper access control in Citrix ADC and Citrix Gateway versions before 13.0-58.30, 12.1-57.18, 12.0-63.21, 11.1-64.14 and 10.5-70.18 and Citrix SDWAN WAN-OP versions before 11.1.1a, 11.0.3d and 10.…
Assigned by hackerone
Jul 10, 2020
CVE-2020-8195
Known exploited
Medium 6.5Improper input validation in Citrix ADC and Citrix Gateway versions before 13.0-58.30, 12.1-57.18, 12.0-63.21, 11.1-64.14 and 10.5-70.18 and Citrix SDWAN WAN-OP versions before 11.1.1a, 11.0.3d and 1…
Assigned by hackerone
Jul 10, 2020
CVE-2020-8196
Known exploited
Medium 4.3Improper access control in Citrix ADC and Citrix Gateway versions before 13.0-58.30, 12.1-57.18, 12.0-63.21, 11.1-64.14 and 10.5-70.18 and Citrix SDWAN WAN-OP versions before 11.1.1a, 11.0.3d and 10.…
Assigned by hackerone
Jul 10, 2020
CVE-2019-20907Medium 5.5In Lib/tarfile.py in Python through 3.8.3, an attacker is able to craft a TAR archive leading to an infinite loop when opened by tarfile.open, because _proc_pax lacks header validation.
Assigned by mitre
Jul 13, 2020
CVE-2020-10987
Known exploited
Critical 9.8The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter.
Assigned by mitre
Jul 13, 2020
CVE-2020-6287
Known exploited
Critical 10.0SAP NetWeaver AS JAVA (LM Configuration Wizard), versions - 7.30, 7.31, 7.40, 7.50, does not perform an authentication check which allows an attacker without prior authentication to execute configura…
Assigned by sap
Jul 14, 2020
CVE-2020-13934High 7.5An h2c direct connection to Apache Tomcat 10.0.0-M1 to 10.0.0-M6, 9.0.0.M5 to 9.0.36 and 8.5.1 to 8.5.56 did not release the HTTP/1.1 processor after the upgrade to HTTP/2.
Assigned by apache
Jul 14, 2020
PreviousPage 29 of 2,031Next

CVSS is the assigning CNA's score where it gives one, otherwise NVD's. The healthcare tag is a documented heuristic (a list of clinical and health IT vendors, and clinical terms in the description), not a classification. The CVE record is authoritative.

Your cookie choices
We use essential cookies to run this site, and, only with your consent, an advertising cookie from Google to measure whether our ads lead to sign-ups and subscriptions. See our for details.