Red Lion Controls N-Tron 700 Series (Update A)
Updated under an hour ago ()
View CSAF Summary Successful exploitation of these vulnerabilities could allow a malicious user to access the device and gain administrative access. This access would allow the user to view, edit, and upload configuration files. Further, a malicious user can cause the switch to reboot by navigating to a specific URL on the device. This action can be scripted on the malicious user's local machine to cause continuous rebooting of the switch. The following versions of Red Lion Controls N-Tron 700 Series are affected: 700 Series <=Firmware_3.11.0 (CVE-2026-32645, CVE-2026-39460, CVE-2026-28745, CVE-2026-33367, CVE-2026-29797, CVE-2026-39453, CVE-2026-33272) 700 Series <=Bootloader_2.0.6.1 (CVE-2026-32645, CVE-2026-39460, CVE-2026-28745, CVE-2026-33367, CVE-2026-29797, CVE-2026-39453, CVE-2026-33272) CVSS Vendor Equipment v3 8.3 Red Lion Controls 700 Series 7 Vulnerabilities Use of Hard-coded Credentials, Insufficiently Protected Credentials, Storing Passwords in a Recoverable Format, Missing Authentication for Critical Function, Download of Code Without Integrity Check, Reachable Assertion, Authentication Bypass Using an Alternate Path or Channel Background Critical Infrastructur…
- Tags
- CISA, ICS
- Related exam domains
- CISSP 4: Communication and Network Security; CISSP 8: Software Development Security; CISM 2: Information Security Risk Management
- Source record id
- /node/25602
- First seen by InfoSec Signals
- 10/9/2026
Source: CISA cybersecurity advisories, Cybersecurity and Infrastructure Security Agency about this source more from it
Exam domain labels come from a keyword heuristic and are study hints, not an official mapping. The summary is the publisher's own text, shortened; the linked record is authoritative.