CVE records

Every CVE as the CVE Program publishes it, refreshed every ten minutes, with NVD's analysis, CISA's known-exploited status and a healthcare tag. Subscribers get the CVEs that match their own systems on My program, by email as they are published. Where the data comes from: sources.

Updated under an hour ago ()

What this means for you

This week: 5,469 CVEs published, 357 critical, and 7 newly confirmed exploited. Add your stack to see whether any of them hit you.

Published in the last 7 days
5,469
Show in the list
Critical, last 7 days
357
Show in the list
Healthcare-tagged, last 7 days
4
Show in the list
Known exploited (CISA KEV)
1,747
Show in the list

Showing CVEs that name the product siemens:simatic_et_200sp_cpu_1514spt_f_2_pn. Show all products

8 CVEs, showing 1 to 8
CVESeverityTitlePublished
CVE-2026-63350Critical 9.6Affected devices do not properly restrict executable content contained in imported trace files.
Assigned by siemens
Oct 13, 2026
CVE-2026-63351Medium 6.1Affected devices do not properly validate and sanitize visual properties of calculated signals contained in imported CSV trace files before rendering them on the Trace page.
Assigned by siemens
Oct 13, 2026
CVE-2026-63352Medium 6.1Affected devices do not properly sanitize calculated signal data contained in imported CSV trace files before rendering it on the Trace page.
Assigned by siemens
Oct 13, 2026
CVE-2026-63353Critical 9.6Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page.
Assigned by siemens
Oct 13, 2026
CVE-2026-63354Critical 9.6Affected devices do not properly validate and sanitize visual marker data contained in imported CSV trace files before rendering it on the Trace page.
Assigned by siemens
Oct 13, 2026
CVE-2026-63355Medium 6.1Affected devices do not properly sanitize signal names contained in imported CSV trace files before rendering them in selection menus on the Trace page.
Assigned by siemens
Oct 13, 2026
CVE-2026-63356Medium 6.1Affected devices do not properly sanitize calculated signal names contained in imported CSV trace files before including them in error messages on the Trace page.
Assigned by siemens
Oct 13, 2026
CVE-2026-63357Medium 6.1Affected devices do not properly sanitize calculated signal data contained in imported calculated signal files before rendering it on the Trace page.
Assigned by siemens
Oct 13, 2026

CVSS is the assigning CNA's score where it gives one, otherwise NVD's. The healthcare tag is a documented heuristic (a list of clinical and health IT vendors, and clinical terms in the description), not a classification. The CVE record is authoritative.

Your cookie choices
We use essential cookies to run this site, and, only with your consent, an advertising cookie from Google to measure whether our ads lead to sign-ups and subscriptions. See our for details.