CVE-2026-8359When processing a request with a URL path starting with /status or /sysinfo, WOSHttpStatusModule.dll is to be loaded to handle such URL patterns.
Updated under an hour ago ()
Does this affect you?
It lists no affected products yet. Add what you run and Signals checks it as products are added.
No exploitation reported and no EPSS estimate yet.
When processing a request with a URL path starting with /status or /sysinfo, WOSHttpStatusModule.dll is to be loaded to handle such URL patterns. The WOSBin_LoadHttpModule function in the dll would be called to set up a "module" object for that module. However, WOSHttpStatusModule.dll is not present in the installation. As a result, a function pointer to WOSBin_LoadHttpModule (which would have been in the export table in WOSHttpStatusModule.dll) is set to NULL, resulting in calling a function at address 0.
- CVSS
- 7.5 HIGH (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Weakness (CWE)
- CWE-476
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- Not given
- NVD analysis
- Deferred
- Record last updated
- Jun 17, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
Affected products
No affected products are listed yet.
References
- https://www.tenable.com/security/research/TRA-2026-45
The CVE record on cve.org NVD's entry