CVE-2026-8032A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7.
Updated under an hour ago ()
Does this affect you?
It lists no affected products yet. Add what you run and Signals checks it as products are added.
No exploitation reported and no EPSS estimate yet.
A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be carried out remotely. The exploit has been published and may be used. Upgrading to version 5.7.1 is sufficient to resolve this issue. The affected component should be upgraded. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
- CVSS
- 7.3 HIGH (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
- Weakness (CWE)
- CWE-259, CWE-798
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- Not given
- NVD analysis
- Deferred
- Record last updated
- Jun 17, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
Affected products
No affected products are listed yet.
References
- https://docs.google.com/document/d/1w1veNs8I3nxsVxbSiIgJmt-4S5a0rW0bvjDvEe7iDr0/edit?usp=sharing
- https://vuldb.com/submit/800792
- https://vuldb.com/vuln/361358
- https://vuldb.com/vuln/361358/cti
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.