Back to CVE records
Medium 6.7Published Aug 19, 2026

CVE-2026-76328SPL Injection through Splunk Web in Splunk Enterprise

Updated under an hour ago ()

Does this affect you?

It affects Splunk Enterprise and 1 other product. Add what you run to find out whether that includes you.

No exploitation reported and no EPSS estimate yet.

In Splunk Enterprise versions below 10.4.1, 10.2.6, 10.0.9, and 9.4.14, a user who holds the "power" Splunk role could store attacker-controlled Search Processing Language (SPL) in a dashboard. When another authenticated user exports the dashboard as a Portable Document Format (PDF) file, Splunk Enterprise runs the injected SPL using the permissions of that user. The injected SPL could access or modify data available to that user. The vulnerability is possible because Splunk Web does not sufficiently validate dashboard content before processing PDF exports. The vulnerability requires the attacker to phish the affected user by tricking them into initiating a request within their browser. The user who holds the "power" Splunk role should not be able to exploit the vulnerability at will. For more information see Generate PDFs of your reports and dashboards (https://help.splunk.com/en/splunk-enterprise/create-dashboards-and-reports/reporting-manual/9.4/report-management/generate-pdfs-of-your-reports-and-dashboards) in the Splunk documentation.

CVSS
6.7 MEDIUM (v3.1, CNA)CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:L
Weakness (CWE)
CWE-77
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
Not loaded for this CVE
Assigned by
cisco
NVD analysis
Analyzed
Record last updated
Aug 27, 2026
First seen by InfoSec Signals
Oct 9, 2026

Affected products

Affected products
Splunk Splunk Enterprise
splunk:enterprise (from the name)
from 10.4 before 10.4.1; from 10.2 before 10.2.6; from 10.0 before 10.0.9; from 9.4 before 9.4.14
CNA record
splunk splunk
splunk:splunk
from 9.4.0 before 9.4.14; from 10.0.0 before 10.0.9; from 10.2.0 before 10.2.6; from 10.4.0 before 10.4.2
NVD

References

  • vendor-advisory

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.