Back to CVE records
Medium 6.5Published Aug 4, 2026

CVE-2026-70368Stunnel: stack-based out-of-bounds read/write in stunnel s_vlog via oversized log message

Updated under an hour ago ()

Does this affect you?

It affects Mobi-Com Polska Sp. z o.o. stunnel and 1 other product. Add what you run to find out whether that includes you.

No exploitation reported and no EPSS estimate yet.

A stack-based out-of-bounds read vulnerability exists in the "s_vlog" function of stunnel, when handling oversized log messages via "vsnprintf". A remote attacker with network access to a stunnel service can send protocol inputs that trigger a log message longer than 1024 bytes, leading to an out-of-bounds stack read and a potential crash. In certain corner cases, the same vulnerability could be used to replace a series of trailing "\n" characters with "\0".

CVSS
6.5 MEDIUM (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
Weakness (CWE)
CWE-125
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
Not loaded for this CVE
Assigned by
redhat
NVD analysis
Awaiting Analysis
Record last updated
Aug 6, 2026
First seen by InfoSec Signals
Oct 9, 2026

Affected products

Affected products
Mobi-Com Polska Sp. z o.o. stunnel
mobi_com_polska_sp_z_o.o:stunnel (from the name)
from 5.68 before 5.80
CNA record
10
CNA record

References

  • vdb-entry, x-refsource-redhat
  • issue-tracking, x-refsource-redhat

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.

Your cookie choices
We use essential cookies to run this site, and, only with your consent, an advertising cookie from Google to measure whether our ads lead to sign-ups and subscriptions. See our for details.