CVE-2026-20177Cisco Industrial Ethernet 1000 Series Switches Denial of Service Vulnerability
Updated under an hour ago ()
Does this affect you?
It affects Cisco Industrial Ethernet Switches. Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
A vulnerability in the handling of management plane packets by Cisco Industrial Ethernet (IE) 1000 Series Switches could allow an unauthenticated, remote attacker to cause the device manager, SSH, or API to become inaccessible.This vulnerability is due to insufficient protection against management plane flooding attacks. An attacker could exploit this vulnerability by sending a high rate of ICMP, SSH, or HTTP traffic to an affected device. A successful exploit could allow the attacker to cause the CPU of the device to increase, resulting in a denial of service (DoS) condition on the device manager web GUI, SSH, or API. Data traffic through the device is not affected.
- CVSS
- 5.3 MEDIUM (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
- Weakness (CWE)
- CWE-770
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- cisco
- NVD analysis
- Awaiting Analysis
- Record last updated
- Aug 20, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
Affected products
Cisco Cisco Industrial Ethernet Switches cisco:industrial_ethernet_switches (from the name) | 1.1; 1.2; 1.8.0; 1.8.2; 1.7.0; 1.3; 1.9.1; 1.6; and 6 more ranges | CNA record |
References
- https://sec.cloudapps.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ie1k-uxq86Lnx
The CVE record on cve.org NVD's entry