Back to CVE records
High 7.8Published Oct 8, 2026

CVE-2026-107612World-accessible IPC shared memory with predictable name in TightVNC Server

Updated under an hour ago ()

Does this affect you?

It affects GlavSoft TightVNC. Add what you run to find out whether that includes you.

EPSS puts the chance of exploitation in the next 30 days at 0.10%, higher than 1% of scored CVEs.

Incorrect permission assignment in GlavSoft TightVNC Server for Windows before 2.8.88 allows a local authenticated user to read or overwrite the inter-process communication handles used between the TightVNC service and its desktop server process. The named shared memory segment in the Global\ namespace that carries the pipe HANDLE values is created with a NULL DACL, and its name is derived from a time-seeded srand(time(0)) value that is predictable to one-second granularity. A low-privileged local process can open the mapping and tamper with the IPC channel of a service running as SYSTEM, potentially leading to disclosure of session data, privilege escalation, or denial of service.

CVSS
7.8 HIGH (v3.1, CNA)CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness (CWE)
CWE-732, CWE-338
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
0.10% (percentile 1)
Assigned by
securin
NVD analysis
Awaiting Analysis
Record last updated
Oct 8, 2026
First seen by InfoSec Signals
Oct 9, 2026

Affected products

Affected products
GlavSoft TightVNC
glavsoft:tightvnc (from the name)
before 2.8.88
CNA record

References

  • issue-tracking
  • release-notes, patch

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.