CVE-2025-66052Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection.
Updated under an hour ago ()
Does this affect you?
It affects vivotek ip7137_firmware. Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
- CVSS
- 7.2 HIGH (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Weakness (CWE)
- CWE-78
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- Not given
- NVD analysis
- Analyzed
- Record last updated
- Jun 17, 2026
- First seen by InfoSec Signals
- Oct 9, 2026
Affected products
vivotek ip7137_firmware vivotek:ip7137_firmware | 0200a | NVD |
References
- https://cert.pl/posts/2026/01/CVE-2025-66049third-party-advisory
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.