Back to CVE records
High 7.2Known exploited (CISA KEV)Published Sep 17, 2024

CVE-2024-8957PTZOptics NDI and SDI Cameras Command Injection via NTP Address Configuration

Updated under an hour ago ()

Does this affect you?

It affects PTZOptics PT30X-SDI and 4 other products. Add what you run to find out whether that includes you.

CISA lists it as known exploited since Nov 4, 2024; federal agencies had to remediate by Nov 25, 2024. Treat that date as your deadline.

PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an OS command injection issue. The camera does not sufficiently validate the ntp_addr configuration value which may lead to arbitrary command execution when ntp_client is started. When chained with CVE-2024-8956, a remote and unauthenticated attacker can execute arbitrary OS commands on affected devices.

CVSS
7.2 HIGH (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness (CWE)
CWE-78
Known exploited
Added to CISA KEV Nov 4, 2024; federal remediation due Nov 25, 2024Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
EPSS (exploitation in the next 30 days)
79.84% (percentile 100)
Assigned by
VulnCheck
NVD analysis
Analyzed
Record last updated
Dec 27, 2025
First seen by InfoSec Signals
Oct 9, 2026

Affected products

Affected products
PTZOptics PT30X-SDI
ptzoptics:pt30x_sdi (from the name)
before 6.3.40
CNA record
PTZOptics PT30X-NDI
ptzoptics:pt30x_ndi (from the name)
before 6.3.40
CNA record
ptzoptics pt30x-sdi_firmware
ptzoptics:pt30x-sdi_firmware
before 6.3.40
CISA ADP
ptzoptics pt30x-ndi_firmware
ptzoptics:pt30x-ndi_firmware
before 6.3.40
CISA ADP
ptzoptics pt30x-sdi_firmware
ptzoptics:pt30x-sdi_firmware
before 6.3.40
NVD
ptzoptics pt30x-ndi-xx-g2_firmware
ptzoptics:pt30x-ndi-xx-g2_firmware
before 6.3.40
NVD

References

  • vendor-advisory, release-notes
  • third-party-advisory
  • us-government-resource
  • third-party-advisory
  • exploit, third-party-advisory

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.