Back to CVE records
High 7.4HealthcarePublished May 14, 2024

CVE-2024-1486Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices

Updated under an hour ago ()

Does this affect you?

It affects GE HealthCare Venue and 21 other products. Add what you run to find out whether that includes you.

EPSS puts the chance of exploitation in the next 30 days at 0.20%, higher than 9% of scored CVEs.

Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices

CVSS
7.4 HIGH (v3.1, CNA)CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness (CWE)
CWE-732
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
0.20% (percentile 9)
Assigned by
GEHC
NVD analysis
Deferred
Record last updated
Aug 16, 2024
First seen by InfoSec Signals
Oct 12, 2026

Affected products

Affected products
GE HealthCare Venue
ge_healthcare:venue (from the name)
R1; R2; from R3 through R3.3; from R4 through R4.2
CNA record
GE HealthCare Venue Go
ge_healthcare:venue_go (from the name)
R2; from R3 through R3.3; from R4 through R4.2
CNA record
GE HealthCare Venue Fit
ge_healthcare:venue_fit (from the name)
from R3 through R3.3; from R4 through R4.2
CNA record
GE HealthCare LOGIQ e
ge_healthcare:logiq_e (from the name)
from R7 through R9.1.4; from R8 through R10.1.3; from R9 through R11.0.2
CNA record
GE HealthCare LOGIQ He
ge_healthcare:logiq_he (from the name)
through R9.3.1
CNA record
GE HealthCare Vivid E
ge_healthcare:vivid_e (from the name)
from E95 before 206; from E90 before 206; from E80 before 206; from E9 113.2 through 113.2
CNA record
GE HealthCare Vivid S
ge_healthcare:vivid_s (from the name)
from 70N before 206; from 60N before 206
CNA record
GE HealthCare Vivid T
ge_healthcare:vivid_t (from the name)
from T8 before 206; from T9 before 206
CNA record
GE HealthCare Vivid iq
ge_healthcare:vivid_iq (from the name)
before 206
CNA record
GE HealthCare Invenia ABUS
ge_healthcare:invenia_abus (from the name)
1.2.3
CNA record
GE HealthCare Invenia ABUS 2.0
ge_healthcare:invenia_abus_2.0 (from the name)
before 2.2.9
CNA record
gehealthcare venue_firmware
gehealthcare:venue_firmware
R1; R2; from R3 through R3.3; from R4 through R4.2
CISA ADP
gehealthcare venue_go_firmware
gehealthcare:venue_go_firmware
R2; from R3 through R3.3; from R4 through R4.2
CISA ADP
gehealthcare venue_fit_firmware
gehealthcare:venue_fit_firmware
from R3 through R3.3; from R4 through R4.2
CISA ADP
gehealthcare logiq_e_firmware
gehealthcare:logiq_e_firmware
from R7 through R9.1.4; from R8 through R10.1.3; from R9 through R11.0.2
CISA ADP
gehealthcare logiq_he_firmware
gehealthcare:logiq_he_firmware
through R9.3.1
CISA ADP
gehealthcare vivid_e_firmware
gehealthcare:vivid_e_firmware
from E95 before 206; from E90 before 206; from E80 before 206; from E9 113.2 through 113.2
CISA ADP
gehealthcare vivid_s_firmware
gehealthcare:vivid_s_firmware
from 70N before 206; from 60N before 206
CISA ADP
gehealthcare vivid_t_firmware
gehealthcare:vivid_t_firmware
from T8 before 206; from T9 before 206
CISA ADP
gehealthcare vivid_iq_firmware
gehealthcare:vivid_iq_firmware
before 206
CISA ADP
gehealthcare invenia_abus_firmware
gehealthcare:invenia_abus_firmware
1.2.3
CISA ADP
gehealthcare invenia_abus_2.0_firmware
gehealthcare:invenia_abus_2.0_firmware
before 2.2.9
CISA ADP

References

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.