CVE-2023-28484In libxml2 before 2.10.4, parsing of certain invalid XSD schemas can lead to a NULL pointer dereference and subsequently a segfault.
Updated under an hour ago ()
Does this affect you?
It affects Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP and 4 other products. Add what you run to find out whether that includes you.
No exploitation reported and no EPSS estimate yet.
Do this next
Free account, 1 product
In libxml2 before 2.10.4, parsing of certain invalid XSD schemas can lead to a NULL pointer dereference and subsequently a segfault. This occurs in xmlSchemaFixupComplexType in xmlschemas.c.
- CVSS
- 6.5 MEDIUM (v3.1, CISA ADP)CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
- Weakness (CWE)
- CWE-476
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- Not loaded for this CVE
- Assigned by
- mitre
- NVD analysis
- Modified
- Record last updated
- Oct 14, 2026
- First seen by InfoSec Signals
- Oct 14, 2026
Affected products
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP siemens:simatic_s7_1500_cpu_1518_4_pn_dp_mfp (from the name) | from V3.1.0 before V3.1.5 | CISA ADP |
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP siemens:simatic_s7_1500_cpu_1518f_4_pn_dp_mfp (from the name) | from V3.1.0 before V3.1.5 | CISA ADP |
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP siemens:siplus_s7_1500_cpu_1518_4_pn_dp_mfp (from the name) | from V3.1.0 before V3.1.5 | CISA ADP |
xmlsoft libxml2 xmlsoft:libxml2 | before 2.10.4 | NVD |
debian debian_linux debian:debian_linux | 10.0 | NVD |
References
- https://gitlab.gnome.org/GNOME/libxml2/-/releases/v2.10.4release-notes
- https://gitlab.gnome.org/GNOME/libxml2/-/issues/491exploit, issue-tracking, patch, vendor-advisory
- https://lists.debian.org/debian-lts-announce/2023/04/msg00031.htmlmailing-list, third-party-advisory
- https://security.netapp.com/advisory/ntap-20230601-0006/
- https://security.netapp.com/advisory/ntap-20240201-0005/
- https://cert-portal.siemens.com/productcert/html/ssa-341067.html
- https://cert-portal.siemens.com/productcert/html/ssa-398330.html
- https://cert-portal.siemens.com/productcert/html/ssa-556635.html
- https://cert-portal.siemens.com/productcert/html/ssa-625862.html
- https://cert-portal.siemens.com/productcert/html/ssa-769027.html
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.