Back to CVE records
Medium 4.3Published Jun 1, 2022

CVE-2022-30115Using its HSTS support, curl can be instructed to use HTTPS directly insteadof using an insecure clear-text HTTP step even when HTTP is provided in theURL.

Updated under an hour ago ()

Does this affect you?

It affects Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP and 12 other products. Add what you run to find out whether that includes you.

No exploitation reported and no EPSS estimate yet.

Using its HSTS support, curl can be instructed to use HTTPS directly insteadof using an insecure clear-text HTTP step even when HTTP is provided in theURL. This mechanism could be bypassed if the host name in the given URL used atrailing dot while not using one when it built the HSTS cache. Or the otherway around - by having the trailing dot in the HSTS cache and *not* using thetrailing dot in the URL.

CVSS
4.3 MEDIUM (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N
Weakness (CWE)
CWE-325
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
Not loaded for this CVE
Assigned by
hackerone
NVD analysis
Modified
Record last updated
Oct 14, 2026
First seen by InfoSec Signals
Oct 9, 2026

Affected products

Affected products
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP
siemens:simatic_s7_1500_cpu_1518_4_pn_dp_mfp (from the name)
from V3.1.0 before V3.1.5
CISA ADP
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP
siemens:simatic_s7_1500_cpu_1518f_4_pn_dp_mfp (from the name)
from V3.1.0 before V3.1.5
CISA ADP
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP
siemens:siplus_s7_1500_cpu_1518_4_pn_dp_mfp (from the name)
from V3.1.0 before V3.1.5
CISA ADP
haxx curl
haxx:curl
from 7.82.0 before 7.83.1
NVD
netapp hci_bootstrap_os
netapp:hci_bootstrap_os
all versions
NVD
netapp clustered_data_ontap
netapp:clustered_data_ontap
all versions
NVD
netapp solidfire,_enterprise_sds_&_hci_storage_node
netapp:solidfire,_enterprise_sds_&_hci_storage_node
all versions
NVD
netapp solidfire_&_hci_management_node
netapp:solidfire_&_hci_management_node
all versions
NVD
netapp h300s_firmware
netapp:h300s_firmware
all versions
NVD
netapp h500s_firmware
netapp:h500s_firmware
all versions
NVD
netapp h700s_firmware
netapp:h700s_firmware
all versions
NVD
netapp h410s_firmware
netapp:h410s_firmware
all versions
NVD
splunk universal_forwarder
splunk:universal_forwarder
from 8.2.0 before 8.2.12; from 9.0.0 before 9.0.6; 9.1.0
NVD

References

  • exploit, third-party-advisory
  • third-party-advisory
  • mailing-list, patch, third-party-advisory
  • vendor-advisory, third-party-advisory
  • mailing-list, third-party-advisory

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.

Your cookie choices
We use essential cookies to run this site, and, only with your consent, an advertising cookie from Google to measure whether our ads lead to sign-ups and subscriptions. See our for details.