CVE-2021-43935ICSMA-21-343-01 Hillrom Welch Allyn Cardio Products
Updated under an hour ago ()
Does this affect you?
It affects Hillrom Welch Allyn Q-Stress Cardiac Stress Testing System and 13 other products. Add what you run to find out whether that includes you.
EPSS puts the chance of exploitation in the next 30 days at 1.15%, higher than 66% of scored CVEs.
Do this next
Free account, 1 product
The impacted products, when configured to use SSO, are affected by an improper authentication vulnerability. This vulnerability allows the application to accept manual entry of any active directory (AD) account provisioned in the application without supplying a password, resulting in access to the application as the supplied AD account, with all associated privileges.
- CVSS
- 8.1 HIGH (v3.1, CNA)CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
- Weakness (CWE)
- CWE-288
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- 1.15% (percentile 66)
- Assigned by
- icscert
- NVD analysis
- Modified
- Record last updated
- Sep 16, 2024
- First seen by InfoSec Signals
- Oct 12, 2026
Affected products
Hillrom Welch Allyn Q-Stress Cardiac Stress Testing System hillrom:welch_allyn_q_stress_cardiac_stress_testing_system (from the name) | from 6.0.0 through 6.3.1 | CNA record |
Hillrom Welch Allyn X-Scribe Cardiac Stress Testing System hillrom:welch_allyn_x_scribe_cardiac_stress_testing_system (from the name) | from 5.01 through 6.3.1 | CNA record |
Hillrom Welch Allyn Diagnostic Cardiology Suite hillrom:welch_allyn_diagnostic_cardiology_suite (from the name) | 2.1.0 | CNA record |
Hillrom Welch Allyn Vision Express hillrom:welch_allyn_vision_express (from the name) | from 6.1.0 through 6.4.0 | CNA record |
Hillrom Welch Allyn H-Scribe Holter Analysis System hillrom:welch_allyn_h_scribe_holter_analysis_system (from the name) | from 5.01 through 6.4.0 | CNA record |
Hillrom Welch Allyn R-Scribe Resting ECG System hillrom:welch_allyn_r_scribe_resting_ecg_system (from the name) | from 5.01 through 7.0.0 | CNA record |
Hillrom Welch Allyn Connex Cardio hillrom:welch_allyn_connex_cardio (from the name) | from 1.0.0 through 1.1.1 | CNA record |
baxter welch_allyn_connex_cardio baxter:welch_allyn_connex_cardio | from 1.0.0 through 1.1.1 | NVD |
baxter welch_allyn_diagnostic_cardiology_suite baxter:welch_allyn_diagnostic_cardiology_suite | 2.1.0 | NVD |
baxter welch_allyn_rscribe_resting_ecg_system baxter:welch_allyn_rscribe_resting_ecg_system | from 5.01 through 7.0.0 | NVD |
baxter welch_allyn_vision_express_holter_analysis_system baxter:welch_allyn_vision_express_holter_analysis_system | from 6.1.0 through 6.4.0 | NVD |
baxter welch_allyn_hscribe_holter_analysis_system_firmware baxter:welch_allyn_hscribe_holter_analysis_system_firmware | from 5.01 through 6.4.0 | NVD |
baxter welch_allyn_q-stress_cardiac_stress_testing_system_firmware baxter:welch_allyn_q-stress_cardiac_stress_testing_system_firmware | from 6.0.0 through 6.3.1 | NVD |
baxter welch_allyn_xscribe_cardiac_stress_testing_system_firmware baxter:welch_allyn_xscribe_cardiac_stress_testing_system_firmware | from 5.01 through 6.3.1 | NVD |
References
- https://www.cisa.gov/uscert/ics/advisories/icsma-21-343-01x-refsource-misc, mitigation, third-party-advisory, us-government-resource
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.