CVE-2021-27408The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch A…
Updated under an hour ago ()
Does this affect you?
It affects hillrom connex_central_station and 8 other products. Add what you run to find out whether that includes you.
EPSS puts the chance of exploitation in the next 30 days at 1.69%, higher than 77% of scored CVEs.
Do this next
Free account, 1 product
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
- CVSS
- 7.5 HIGH (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Weakness (CWE)
- CWE-125
- Known exploited
- Not in CISA's KEV catalog
- EPSS (exploitation in the next 30 days)
- 1.69% (percentile 77)
- Assigned by
- icscert
- NVD analysis
- Modified
- Record last updated
- Aug 3, 2024
- First seen by InfoSec Signals
- Oct 12, 2026
Affected products
hillrom connex_central_station hillrom:connex_central_station | before 1.8.6 | NVD |
hillrom connex_device_integration_suite_network_connectivity_engine hillrom:connex_device_integration_suite_network_connectivity_engine | before 5.3 | NVD |
hillrom connex_integrated_wall_system hillrom:connex_integrated_wall_system | before 2.43.02 | NVD |
hillrom connex_spot_monitor hillrom:connex_spot_monitor | before 1.52 | NVD |
hillrom connex_vital_signs_monitor hillrom:connex_vital_signs_monitor | before 2.43.02 | NVD |
hillrom service_monitor hillrom:service_monitor | before 1.7.0.0 | NVD |
hillrom service_tool hillrom:service_tool | before 1.10 | NVD |
hillrom software_development_kit hillrom:software_development_kit | before 3.2 | NVD |
hillrom spot_vital_signs_4400 hillrom:spot_vital_signs_4400 | before 1.11.00; before 1.11.00 | NVD |
References
- https://us-cert.cisa.gov/ics/advisories/icsma-21-152-01x-refsource-misc, mitigation, third-party-advisory, us-government-resource
The CVE record on cve.org NVD's entry
The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.