Back to CVE records
Medium 6.5HealthcarePublished Sep 11, 2020

CVE-2020-16216Philips Patient Monitoring Devices Improper Input Validation

Updated under an hour ago ()

Does this affect you?

It affects Philips IntelliVue patient monitors and 14 other products. Add what you run to find out whether that includes you.

EPSS puts the chance of exploitation in the next 30 days at 0.70%, higher than 52% of scored CVEs.

In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.

CVSS
6.5 MEDIUM (v3.1, NVD)CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness (CWE)
CWE-20
Known exploited
Not in CISA's KEV catalog
EPSS (exploitation in the next 30 days)
0.70% (percentile 52)
Assigned by
icscert
NVD analysis
Modified
Record last updated
Aug 4, 2024
First seen by InfoSec Signals
Oct 12, 2026

Affected products

Affected products
Philips IntelliVue patient monitors
philips:intellivue_patient_monitors (from the name)
MX100; MX400-550; MX600; MX700; MX750; MX800; MX850; MP2-MP90
CNA record
Philips IntelliVue
philips:intellivue (from the name)
X2; X3; through N
CNA record
philips patient_information_center_ix
philips:patient_information_center_ix
b.02; c.02; c.03
NVD
philips performancebridge_focal_point
philips:performancebridge_focal_point
a.01
NVD
philips intellivue_mp2-mp90_firmware
philips:intellivue_mp2-mp90_firmware
all versions
NVD
philips intellivue_mx100_firmware
philips:intellivue_mx100_firmware
all versions
NVD
philips intellivue_mx400_firmware
philips:intellivue_mx400_firmware
all versions
NVD
philips intellivue_mx850_firmware
philips:intellivue_mx850_firmware
all versions
NVD
philips intellivue_x2_firmware
philips:intellivue_x2_firmware
all versions
NVD
philips intellivue_x3_firmware
philips:intellivue_x3_firmware
all versions
NVD
philips intellivue_mx800_firmware
philips:intellivue_mx800_firmware
all versions
NVD
philips intellivue_mx750_firmware
philips:intellivue_mx750_firmware
all versions
NVD
philips intellivue_mx700_firmware
philips:intellivue_mx700_firmware
all versions
NVD
philips intellivue_mx600_firmware
philips:intellivue_mx600_firmware
all versions
NVD
philips intellivue_mx550_firmware
philips:intellivue_mx550_firmware
all versions
NVD

References

  • x-refsource-misc, third-party-advisory, us-government-resource

The CVE record is authoritative. Products marked “from the name” were identified from the CNA's free-text names, not a CPE, and are matched less certainly. This product uses the NVD API but is not endorsed or certified by the NVD.

Your cookie choices
We use essential cookies to run this site, and, only with your consent, an advertising cookie from Google to measure whether our ads lead to sign-ups and subscriptions. See our for details.